Senseca HD2010UC/A.kit2 Class 2 Integrating Sound Level Meter And Analyzer
Specifications
- Brand
- Senseca
- Part Number
- Senseca HD2010UC/A.kit2 Class 2 Integrating Sound Level Meter And Analyzer
- Category
- Meter
- Availability
- In Stock
Product Description
Senseca products, including Senseca HD2010UC/A.kit2 Class 2 Integrating Sound Level Meter And Analyzer, are sourced through parallel import channels and delivered to our customers worldwide with speed and reliability. Even if Senseca HD2010UC/A.kit2 Class 2 Integrating Sound Level Meter And Analyzer is not listed on our website, you are welcome to request a price quote — our team will respond promptly with a tailored offer.TECHNICAL SPECIFICATIONSStandards½ inch Microphone Dynamic Range Linearity range Acoustic Parameters Frequency WeightingsTime Weighting Integration Spectrum AnalysisStatistical AnalysisCombined Data loggingClass 1 or 2 Group X according to IEC 61672-1:2013 Approval according to IEC 61672-1:2002 (I.N.RI.M. Approval Certificate No. 07-0124-02)Class 1 or 2 according to IEC 60651:2001 and IEC 60804:2000 Class 1 according to IEC 61260:1995 and IEC 61260-1:2014Type 1 or 2 according to ANSI S1.4-1983 and S1.43-1997 Class 1-D, order 3, Extended range according to ANSI S1.11-1986UC52 condenser type, pre-polarized, for free field 30 dBA ÷ 143 dB Peak 80 dBSpl, Leq, LeqI, SEL, LEP,d, Lmax, Lmin, Lpk, Dose, Ln Simultaneous A, C, Z (only C and Z for Lpk)Simultaneous FAST, SLOW, IMPULSE From 1s to 99 hours with Back-Erase functionParallel CPB filters in real time complying with class 1 specifications according to IEC 61260• Octave bands from 32 Hz to 8 kHz• Third octave bands from 25 Hz to 12.5 kHz (“Third Octave” option) Average spectrum (AVR) mode – Multi-spectrum in “REPORT” modeIt displays up to 3 percentile levels, between L1 and L99 Probability distribution and percentile level calculation from L1 to L99• Parameter: LFp, Leq, Lpk A, C or Z -weighted (only C or Z for Lpk)• Sampling frequency: 8 samples/second Classification: Classes of 0.5 dBParallel profiles, reports, events acquisition Record of measuring reports with programmable intervals from 1 s to 1 hour with a customizable set of 5 parameters, completestatistical analysis and frequency spectra.Profile Data Logging• Calculation of 5 freely-programmable event parameters• Average spectrum calculation by octave and third octave bands• Calculation of statistical levels from L1 to L99• Event identification trigger with programmable threshold and duration filter• External and manual trigger Reverberation time measurement using sound source interruption or impulse response integrationReverberation time calculation in 1/3 octave requires option HD2010.O1 “Third Octave”.1 profile with sampling 1/8 s and 3 profiles with 2 samples/second, 5 parameters profiles in “Report” mode with minimum sampling interval 1s.Spectrum Data LoggingProgrammable sampling from 1 second to 1 hour (AVR mode). Multi-spectrum data logging in “Report” mode with minimumsampling interval 1s.DisplayGraphic backlit LCD display 128 x 64• 3 parameters in numeric format• Profile LAFp with 8 samples/second• Octave band spectrum from 32 Hz to 8 kHz• Third octave band spectrum from 25 Hz to 12.5 kHz (option “Third Octave” )• Graph of sound level probability distribution• Graph of percentile levels from L1 to L99Analysis of eventsReverberation Time (option HD2010.O4)Memory Input/OutputPC ProgramsOperating Conditions Power Supply Dimensions and weightInternal, equal to 8 MB (4 profiles for 23 hours or over 23 recording days of 3 parameters + spectra per minute)External, via the HD2010MC memory card interface, using MMC or SD cards up to 2 GB• RS232 serial and USB interfaces• AC output (LINE)• DC output Noise Studio (supplied with the instrument): PC interface for data download, set up and instrument management.Licensed software modules to be enabled by hardware key.• NS1“Workers protection” module. Analysis of noise in the workplace in accordance with ISO 9612/2011 and UNI 9432/2011.• NS2A“Acoustic pollution” module. Analysis of environmental noise. Analysis of the noise climate and assessment of noisefrom road, rail and airport according to the law. Some of the functions need option “Third octaves”.• NS3“Acoustic Insulation” module. Evaluation of airborne sound insulation, impact noise and sound absorption; buildingsinsulation classification (UNI 11367). Some of the calculation require option “Third octaves” and option “Reverberationtime” installed in the sound level meter. Calculation according to ISO 16283, ISO 717 and ISO 354.• NS4 “Monitor” module. Acquisition in real time on PC. Synchronized audio recording. Remote monitoring and data capture.Connection via Modem.• NS5”Environmental Noise” module: environmental noise analysis. Noise sources identification with threshold conditions.Tonality and impulsiveness evaluation. Some of the functions require „Third octave“ option.Working temperature ‑10…50 °C, 25…90% RH (not condensing), 65…108 kPa. Protection degree: IP644.8 V / 2.1 A NiMH rechargeable battery or external 5÷24 Vdc / 500 mA 445 x 100 x 50 mm equipped with preamplifier, 740 g (with batteries)www.deltaohm.com - [email protected]Rev. 2.0 - 06/22
Technical Documents
Contact us for the best price and fast delivery.