Nederlands
Senseca LP471LUM2 Luminance Probe
1/6
Senseca LP471LUM2 Luminance Probe 1 Senseca LP471LUM2 Luminance Probe 2 Senseca LP471LUM2 Luminance Probe 3 Senseca LP471LUM2 Luminance Probe 4 Senseca LP471LUM2 Luminance Probe 5 Senseca LP471LUM2 Luminance Probe 6
Delivery
Fast delivery across Europe
Quality
100% original parts
Support
Technical advice available
Senseca logo Senseca

Senseca LP471LUM2 Luminance Probe

In Stock
|
Part Number: LP471LUM2
Probe

Specifications

Brand
Senseca
Part Number
LP471LUM2
Category
Probe
Availability
In Stock

Product Description

Luminance ProbeLP 471 UVB probe for the measure of UVB IRRADIANCE 1.0·10-3 1.000…19.999 20.00…199.99 200.0…1999.9Measuring range (W/m2):…999.9·10-3 2 -3 0.1·10 0.001 0.01 0.1 Resolution (W/m ):Spectral range:280nm…315nm (Peak 305nm...310nm)Calibration uncertainty:<5%f3 (linearity):<2%f4 (instrument reading error):±1digitf5 (fatigue):<0.5%Drift after 1 year:<2%Working temperature:0…50°CRadiometric probe for IRRADIANCE measurement, in the spectral range 280nm…315nm, peak 305nm ... 310nm,Measurement range: 1.0·10-3W/m2…2000W/m2.Combined probe LP 471 P-A with two sensors for the measure ofILLUMINANCE and UVA IRRADIANCE Illuminance Measuring range (lux):0.10…199.9 …1999.9 …19999 …199.99·103 Resolution (lux):0.01 0.1 1 0.01·103 Spectral range:in agreement with standard photopic curve V(λ) <0.05%K α (temp. coefficient) f6 (T)Calibration uncertainty:<4% f’1 (in agreement with photopic response V(λ)):<6% f2 (response according to the cosine law):<3% <1% f3 (linearity):f4 (instrument reading error):<0.5% f5 (fatigue):<0.5% Class:B Drift after 1 year:<1% Working temperature:0…50°C Reference StandardsCIE n.69 - UNI 11142 Please refer to the spectral response of the LP471PHOT probeUVA Irradiance Measuring range (μW/cm2):Resolution (μW/cm2):Spectral range:Calibration uncertainty:f2 (response according to the cosine law):f3 (linearity):f4 (instrument reading error):f5 (fatigue):Drift after 1 year:Working temperature:Typical response curve: LP 471 UVB 1 0,9Relative spectral response0,8 0,7 0,6 0,5 0,4 0,3 0,20.10…199.99 …1999.9 …19999 …199.99·103 0.01 0.1 1 0.01·103 315nm…400nm (Peak 360nm)<5% <6% <1% ±1digit <0.5% <2% 0…50°CPlease refer to the spectral response of the LP471UVA probe0,1 0 250260270280290300310320330340350λ (nm)LP 471 UVC probe for the measure of UVC IRRADIANCE 1.0·10-3 Measuring range (W/m2):1.000…19.999 20.00…199.99 200.0…1999.9 …999.9·10-3 Resolution (W/m2):0.1·10-3 0.001 0.01 0.1 220nm…280nm (Peak 260nm)Spectral range:Calibration uncertainty:<5%f3 (linearity):<1%f4 (instrument reading error):±1digitf5 (fatigue):<0.5%Drift after 1 year:Spectral range:<2%Working temperature:LP SILICON-PYRA probe for the measure of GLOBAL SOLAR RADIATION 1.0·10-3 …1.000…19.999 20.00…199.99 200.0…1999.9 Measurement range (W/m2):999.9·10-3 2 -3 0.1·10 0.001 .01 0.01 Resolution (W/m ):0…50°CRadiometric probe for IRRADIANCE measurement, in the spectral range 220nm…280nm, peak 260nm,UVC. Measurement range: 1.0·10-3W/m2…2000W/m2.400 nm … 1100 nmCalibration uncertainty:f2 (response according to the cosine law):f3 (linearity):<3%f4 (instrument reading error):±1 digitf5 (fatigue):<0.5%<3% <1%Drift after 1 year:<2%Working temperature:0…50°CTypical response curve: LP 471 UVC1.501 0,9Relative spectral response1.25Spectral irradiance Wm-2 nm-1Relative spectral response0,8 0,7 0,6 0,5 0,4 0,3 0,20.75Pyranometer LP Silicon-PYRA040.50Solar spectrum A.M. 1.5 0.250,1 0 200Pyranometer LP PYRA 02, LP PYRA 03,LP PYRA 10 1.00210220230240250λ (nm)260270280290300 0.00 2505007501000125015001750Wavelength nm20002250250027503000

PROBESENSECALUMINANCE PROBESENSECA LP471LUM2LP471LUM2 LUMINANCELP471LUM2 LUMINANCE PROBESENSECA LP471LUM2 LUMINANCE
Price on request

Contact us for the best price and fast delivery.

Similar Products