English
Senseca HD1K-015GM030A Flow Switch
1/3
Senseca HD1K-015GM030A Flow Switch 1 Senseca HD1K-015GM030A Flow Switch 2 Senseca HD1K-015GM030A Flow Switch 3
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
Senseca logo Senseca

Senseca HD1K-015GM030A Flow Switch

Op voorraad
|
Artikelnummer: HD1K-015GM030A
Switch

Specificaties

Merk
Senseca
Artikelnummer
HD1K-015GM030A
Categorie
Switch
Beschikbaarheid
Op voorraad

Productbeschrijving

PROFIBUSEx II (1) G [Ex ia] IIC Ex II (1) D [Ex iaD]Ex II (1) G [Ex ia] IIC/IIB Ex II (1) D [Ex iaD]Ex II (1) G [Ex ia] IIC/IIB Ex II (1) D [Ex iaD]Ex II (1) G [Ex ia] IIC/IIB Ex II (1) D [Ex iaD]MU500-ExPMT50-Ex-2/-3TG50-ExSTL50-ExTransducerTransducerTemperature monitorSafety temperature limiter according to DIN EN 14597Measurement input:Pt100, switchable to 13 measurement ranges Pt1000, switchable to 16 measurement rangesAuxiliary voltage:85..253 V AC/110..125 V DC 10..30 V AC/DC Working temperature:-10...+60 °CPMT50Ex-2 Measurement input:Resistance measurement 0..20 kΩ, Potentiometer measurement 1..100 kΩ PMT50Ex-3Measurement input:Pt100, Pt1000 and thermocouples J, K, N and S Pt100, 3-wire, -100,0..+600,0 °CPt1000, 3-wire, -100,0..+300,0 °C Typ J (Fe-CuNi) -100,0..+800,0 °C Typ K (NiCr-Ni) -150..+1200 °CTyp N (NiCrSi-NiSi) -150..+1200 °C Typ S (Pt10Rh-Pt) -50..+1600 °C Output:0/4 ..20 mA, 0/2 ..10 V DC galvanically isolated, max. 2 alarm outputs Modbus, Profibus DPMeasurement input:Pt100, Pt1000 and thermocouples J, K, N and S Pt100, 3-wire, -100,0..+600,0 °CPt1000, 3-wire, -100,0..+300,0 °C Typ J (Fe-CuNi) -100,0..+800,0 °C Typ K (NiCr-Ni) -150..+1200 °CTyp N (NiCrSi-NiSi) -150..+1200 °C Typ S (Pt10Rh-Pt) -50..+1600 °C Output:0/4 ..20 mA, 0/2 ..10 V DC galvanically isolated 2 alarm outputsMeasurement input:PT100, 3-wire, -100 .. +600 °C Typ J (Fe-CuNi) -100 .. +800 °C Typ K (NiCr-Ni) -150 .. +1200 °CTyp N (NiCrSi-NiSi) -150 .. +1200 °C Typ S (Pt10Rh-Pt) 0 .. 1600 °C Auxiliary voltage:230 V AC +/-10 % 115 V AC +/-10 % 24 V DC +/-15 % Working temperature:-10 .. 55 °CIntrinsic safety „i“Intrinsic safety „i“Intrinsic safety „i“Intrinsic safety „i“Housing IP 30, optionally IP 20Housing IP 30, optionally IP 20Housing IP 30, optionally IP 20IP 20Gas or dust mixtures of Equipment group IIGas or dust mixtures of Equipment group IIGas or dust mixtures of Equipment group IIGas or dust mixtures of Equipment group IIfor connection of sensors from Zones 0, 1, 2, 20, 21, 22for connection of sensors from Zones 0, 1, 2, 20, 21, 22for connection of sensors from Zones 0, 1, 2, 20, 21, 22for connection of sensors from Zones 0, 1, 2, 20, 21, 22More information can be found in the product information Temperature or online on www.ghm-messtechnik.de15

FLOWSWITCHSENSECAFLOW SWITCHSENSECA HD1K-015GM030AHD1K-015GM030A FLOW SWITCHSENSECA HD1K-015GM030A FLOW
Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.

Vergelijkbare Producten