Senseca GLMU400MP-UNI-K21-AV010-PGR-TGR-MGR 4 Pole Conductivity Transmitter Glmu400mp-uni
Specificaties
- Merk
- Senseca
- Artikelnummer
- GLMU400MP-UNI-K21-AV010-PGR-TGR-MGR
- Categorie
- Transmitter
- Beschikbaarheid
- Op voorraad
Productbeschrijving
4 Pole Conductivity Transmitter Glmu400mp-uniCompact Conductivity Measuring Transducer GLMU● ● ● ● ●Local display of conductivity and temperature Freely scalable output scalesVariable temperature-compensation type With local display and galvanic isolation4 to 20 mA version with 2 wires: Power supply via current loop (optionally with 0-10V 3-wire)Features The GLMU is used for drinking water and surface water monitoring,fish husbandry, aquariums and measurement in contaminated solutions and waste water or monitoring of neutralisation.The 4-pole measuring cell of the GLMU-400-MP is especially wellsuited for use for higher salt concentrations based on theinsensitivity to dirt.The GLMU has a local display of conductivity and temperature. The output signal is freely scalable and the measuring range andtemperature compensation type can be selected by the customer.Versions GLMU-200-MPGLMU-400-MPGLMU-400-MP-UNIIncl. 2-pole conductivity measuring cell, compact, single measuring cellIncl. 4-pole conductivity measuring cell, highquality, dirt-resistant measuring cellUniversally configurable measuring transducer without measuring cell, forconnection of arbitrary measuring cellsSpec.resistanceIn kOhm*cm:5.0..100.0 0.50..10.00 In Ohm*cm:50..1000 5.0..100.0In kOhm*cm:0.0..200.0 0.00..20.00 In Ohm*cm:1..5000 1.0..500.0 1.00..50.00In kOhm*cm:0..200 0..2000TDSIn mg / l:0.0..200.0 0..2000In mg / l:0.0..200.0 0..500.0 0..2000 In g / l:0.0..20.0 0..200In mg / l:0.0..200.0 0.0..20.00Salinity0.0..70.0 (PSU)0.0..70.0 (PSU)Temperature Measuring cell Accuracy Conductivity Temperature Measuring cellconnection Cell constant-25..+50 °C (device) 0.0..80.0 °C (measuring cell) : Conductivity measuring cell with 2/4pole for various applications: ± 0.5 % of measured value ± 0.3 % FS (-RW: -1 % of measured value ±0,3 % FS): ±0.2 °C ±1 digit : 7-pole diode socket: K = 0.30..1.20 freely selectable (-RW: 0.03..0.12) Temperature compensationoff : No compensation Lin : Linear compensation (of 0.3..3.0 %/K) nLF : non-linear compensation for naturalwater according to EN27888 (DIN 38404) Output signal : 4..20 mA, (2-wire)0..1 V or 0..10 V (3-wire) Auxiliary energy : 12..30 V DC at 4..20 mA 18..30 V DC at 0..10 VPermissible resistance : RA [Ω] = (UV [V] - 12V) / 0.02 A Permissible load: RL > 3000 Ω Display : 10 mm height, 4-digit display Electrical connection: Angle connector according toEN 175301-803/A, Housing : ABS Ingress protection : IP65 (excluding 7-pole measuring cellconnection socket)DimensionTechnical data GLMU-200MPGLMU-400-MP GLMU-200-MP-RWMeasuring (Decimal point and resolution can be selected by the ranges customer. Specification of the min. and max.possible measuring range) ConductivityIn μS /cm:0.0..200.0 0..2000 In mS/ cm:0.00..20.00 0.0..200.0pi_gr_glmu_e V2.00-00In μS /cm:0.0 ... 200.0 0 ... 2000 In mS/ cm:0.00..20.00 0.0..200.0 0..500In μS /cm:0.0..200.0 0.0..20.001
Technische Documenten
Neem contact met ons op voor de beste prijs en snelle levering.