Senseca FS3T-GE Front Panel With 3 Push-buttons
Specificaties
- Merk
- Senseca
- Artikelnummer
- FS3T-GE
- Categorie
- Panel
- Beschikbaarheid
- Op voorraad
Productbeschrijving
TRANSMITTERISOISOsealingS 10S 11S 20A 10S 10 RELApplication:S 11 RELPressure transmitter (relative pressure, zero output at atmospheric pressure)Pressure measuring transducer (Standard, zero output at ambient pressure)Suitable for all applications in machine and systems engineering, automotive technologyas well as cooling and air conditioning technology.Pressure measuring transducer (Flush, zero output at ambient pressure)S 20 RELPressure measuring transducer (Standard, zero output at ambient pressure)1, 40,1.6, 60,2.5, 100,4, 160,6, 250,10, 400,16, 60025,ÜL:2 803.2 1205 2008 32012 50020 80032 120050BD:5 40010 55010 80017 100034 120034 1700100 2400100S 10 ABSPressure measuring transducer (Standard, absolute, zero output at vacuum)S 11 ABSPressure measuring transducer (Flush, absolute, zero output at vacuum)S 20 ABSPressure measuring transducer (Standard, absolute, zero output at vacuum)General:4 ... 20 mA, 2-wire, RA [Ω] < (Uv [V] - 8V) / 0.02 A 0 ... 10 V, 3-wire, RL > 10 kΩ(other output signals upon request)Auxiliary energy Uv:Piezoresistive pressure sensor with temperature compensation. Completely welded andstainless steel design, filled food safe (up to 16 bar), thin film strain (above 25 bar).8 ... 30 V DC (for output 4 ... 20 mA) 14 ... 30 V DC (for output 0 ... 10 V)Specifications:Accuracy: *≤1.0 % FS (optional: ≤0.5 % FS)* = including non-linearity, hysteresis, zero point and scale error. Corresponds to error of measurement per IEC 61298-2.Sensor adjusted in vertical mounting position with lower pressure connection.Measuring ranges:in bar (other values upon request)S 10 / S 11 REL:S 11 / S 20 REL:0.1, 0.16, 0.25, 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400,600, S 20 REL only: 1000, 1600S 10 / S 11 ABS:S 11 / S 20 ABS:S 10 ABS:0.25, 0.4, 0.6, 1, 1.6, 2.5, 4, 6, 10, 16, S 20 ABS only: 20, 40 0.8 ... 1.2,Available overload pressure limits:3-fold at measuring range <10 bar (150 psi) 2-fold at measuring range ≥10 bar (150 psi)Output signal:4 ... 20 mA (0 ... 10 V - refer to options; others upon request)Non-Linearity:≤0.5 % FS (optional: ≤0.25 % FS)Zero Offset:≤0.5 % FS (typ.), ≤0.8 % FS (max.), (Optional: ≤0.15 % FS (typ.), ≤0.4 % FS (max.))Hysteresis:≤0.16 % FSRepeatability:≤0.1 % FSLong-term drift:≤0.1 % FS (according to IEC 61298-3)Response time: T90≤4 msPermitted temperature of measurement media:0 ... +80 °C (optional: -30 ... +100 °C)Ambient temperature:0 ... +80 °C (optional: -20 ... +100 °C)Storage temperature:-20 ... +80 °CTemperature compensated area:0 ... +80 °CTemperature error in compensated area:≤1.0 % FS (typ.), ≤2.5 % FS (max.)Material:Parts coming into contact with pres. mediaPressure connection:316 LPressure sensor:316 L (as of 10 bar rel. 13 ... 8 PH)Housing:316 LPressure connection:G ¼ A, DIN 3852-E with NBR sealingProtection rating:IP65 or IP67 with cableElectric connection:elbow-type plug acc. to EN 175301-803/A or connection cable, cable length 2 mElectric protections:reverse voltage and short-circuit protectionWeight:approx. 80 gOptions:Absolute pressure: (0 ... 1 bar abs. to 0 ... 25 bar abs.) Under pressure: (-1.0 ... +1.5 bar, -1.0 ... +3.0 bar, -1.0 ... +9.0 bar)G2: Higher sensor accuracy (class 0.5) T2: Extended temperature range: -30 ... +100 °CV2: Output signal 0 ... 10 V Fixed connecting cable: 2 m with bend protection (instead of elbow-type plug, protection rating: IP67)Permissible impedance:RA [Ω] ≤ (Uv [V] - 10 V) / 0.02 A (for output 4 ... 20 mA)Permissible load:RL > 10 kOhm (for output 0 ... 10 V)Auxiliary energy:10 ... 30 V DC (14 ... 30 V DC for output 0 ... 10 V)Accuracy:deviation from ≤0.5 (setting of cut-off point) parameter (% of span): ≤0.25 (setting of tolerance band, BFSL)LOGGER- / BUS SYSTEMSMB:TRANSMITTERMeasuring range (MR), Overload limit (OL), Burst pressure (BP):Repeatability (% of Span): ≤0.1 % Stability/year (% of Span): ≤0.2 (at reference conditions)Hysteresis (% of Span): ≤0.1 Permissible temperature of media: -30 ... +100 °C (refer to options)Operating temperature ambient: -30 ... +100 °C Compensated temperature range: 0 ... +80 °CTemperature coefficient: ≤0.02 % FS / K (or ≤0.04 % FS for MB ≤0.25 bar)Housing:stainless steel 1.4435 (IP65)Pressure connection:(other upon request)Type S 10 / 20... :G ½ B, other upon requestType S 11... :G 1 B (up to 1.6 bar), G ½ B (from 2.5 ... 600 bar)Mounting position:anyElectric connection:standard via elbow-type plug EN 175301-803/AElectric protections:reverse voltage protection, over voltage and short-circuitOptions:Special measuring range Media temperature: -40 ... +125 °C (S 10 / 20 only)Media temperature: -30 ... +125 °C (S 11 only) Media temperature: -20 ... +150°C (S-11 only with cooling section)Output signal 0 ... 10 V (other upon request) Ex-protection upon requestwww.greisinger.de | 59TEMPERATURE PROBESpecifications:Output signal:DISPLAY / CONTROLLERPRESSURE MEASURING TRANSDUCERFOR OVER/UNDER AND ABSOLUTE PRESSUREPRESSURE TRANSMITTER
Technische Documenten
Neem contact met ons op voor de beste prijs en snelle levering.