English
Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500
1/6
Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 1 Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 2 Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 3 Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 4 Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 5 Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500 6
Levering
Snelle levering in NL en BE
Kwaliteit
100% originele onderdelen
Support
Technisch advies beschikbaar
Senseca logo Senseca

Senseca CVT500-1/5-0-5 Current And Voltage Transmitter Cvt500

Op voorraad
|
Artikelnummer: CVT500-1/5-0-5
Transmitter

Specificaties

Merk
Senseca
Artikelnummer
CVT500-1/5-0-5
Categorie
Transmitter
Beschikbaarheid
Op voorraad

Productbeschrijving

Senseca Germany GmbH Tenter Weg 2-8 | 42897 Remscheid | GERMANY Phone +49 2191 9672-0 | info(at)senseca.comProduktinformationCurrent and Voltage Transmitter CVT500Case: Polycarbonate, UL94V-0TS 35 acc. to DIN EN 60715:2001-09 : approx. 200 g : screw terminals, max. 2.5 mm²: case IP30, terminals IP20 acc. to BGV A3Weight Connection Protection classDimensions● Measuring input for DC- and sinusoidal AC-signals ● Arithmetic average value measurement RMS calibrated● Frequency range 40..200 HzCharacteristics Transmitter CVT 500 convert current or voltage signals toproportional industry standard signal 0/4..20 mA, 0/2..10 V DC.Direct measurement of currents up to 5 A and voltages up to 400 V are possible.DIN rail mounting TS35Connection diagram StandardCustom rangeOutputTechnical data Power supply Supply voltage : 230 V AC ±10 % or 24 V DC ±15 %Frequency AC : 47..63 Hz Power consumption: < 3 VA Operating temperature: -10..+50 °C CE-conformity : EN 61326-1:2013; EN 60664-1:2007 Inputs Accuracy: ≤ 0.5 % (≤ 0.2 % single adjustment) Frequency : 40..200 Hz (other ranges on request)Standard measuring ranges Current : 0..1 A and 0..5 A sinusoidal or DC Ri: 20 mΩ (5 A-input) or 100 mΩ (1 A-input ) Overload : 2-times, 4-times max. 5 sVoltage : 0..125 V and 0..250 V AC or DC Ri : 600 kΩ (125 V-) or 1,2 MΩ (250 V-input)Overload : max. 500 V AC/DC Custom measuring ranges Voltage : end value in range 0.1..400 V AC/DCRi : 4.8 kΩ/V Overload : 5-times UN, max. 500 V AC/DC Current : end value in range 0.001..5 A AC/DCRi : 100 mΩ ÷ (custom range [A]) Overload : 2-times, 4-times max. 5 s End value: adjustable ± 5 % Output Output changing Voltage/current : link between terminal 8 and 9Current output : 0/4..20 mA selectable, burden ≤ 500 Ω Rise time (T90) : < 650 msBurden error : < 0.1 % (RL = <200 Ω), < 0.2 % (RL = <500 Ω) Voltage : 0/2..10 V selectable, load max. 10 mApi-ma-CVT500_E V1.02-00Ordering code 1.CVT500 -2.-3.-1. Current ranges 0 not installed (custom measuring range voltage) 1/5 standard device 0..1 A and 0..5 A AC / DC2. Voltage ranges 0 not installed (custom measuring range current) 125 / 250standard device 0..125 V and 0..250 V AC/DC3. Supply voltage 0 230 V AC ± 10 % 5 24 V DC ± 15 %1

CURRENT ANDCVT500-1/5-0-5TRANSMITTER CVT500VOLTAGE TRANSMITTERAND VOLTAGE TRANSMITTER CVT500SENSECA CVT500-1/5-0-5 CURRENTCVT500-1/5-0-5 CURRENT AND VOLTAGE TRANSMITTER
Prijs op aanvraag

Neem contact met ons op voor de beste prijs en snelle levering.